Specifications
|
Model
|
FSM-50R12: Mass fusion splicer up to 12-fiber
FSM-50R8: Mass fusion splicer up to 8-fiber
|
Applicable fibers
|
SM (ITU-T G.652), MM (ITU-T G.651), DS (ITU -T
G.653), NZDS (ITU-T G.655)
|
Fiber Count
|
FSM-50R12: Single, 2, 4, 5, 6, 8, 10 and 12
FSM-50R8: Single, 2, 4, 5, 6 and 8
|
Fiber cleaved length
|
10mm
|
Actual average splice loss
|
0.05dB with SM, 0.02dB with MM, 0.08dB with DS, and 0.08dB with NZDS. Measured by cut-back method relevant to ITU-T and IEC
standards.
|
Splicing time
|
Typical 20seconds
|
Return loss
|
>>60dB
|
Splicing modes
|
40 user programmable modes and up to 60 modes for
reference (factory predetermined setting).
|
Splice loss estimate
|
Available
|
Storage of splice result
|
FSM50R12: The last 400 results to be stored in the internal memory.FSM50R8: The last 500 results to be stored in the internal memory.
|
Fiber display
|
X / Y, or both X and Y simultaneously.
|
Magnification
|
FSM-50R12: 35x丂丂FSM-50R8: 49x
|
Viewing method
|
Two CMOS cameras and 5.6inch color LCD monitor.
|
Operating condition
|
0 to 3,660m above sea level, 0 to 95%RH
and -10 to 50 ℃ respectively.
|
Mechanical proof test
|
2N
|
Tube heater
|
Built-in tube heater with 10 heating modes
and up to 20 modes for reference.
|
Tube heating time
|
Typical 40seconds with FP-04(T), 45seconds
with FP-05 protection sleeves.
|
Applicable protection sleeve length
|
60mm and 40mm
|
No.of splice/heating with battery
|
Typical 70 cycles with BTR-06(S) / Typical 140
cycles with BTR-06(L).
|
Power supply
|
Auto voltage selection from 100 to 240V AC or 10 to
15V DC with ADC-11, 13.2V DC with BTR-06(S)/(L).
|
Terminals
|
USB 1.1 (USB-B type) for PC communication.
Video terminal RCA video jack / NTSC.
|
Wind protection
|
Max. wind velocity of 15m/s.
|
Dimensions
|
150W x 150D x 150H (mm)
|
Weight
|
2.2 kg (2.7kg including AC adapter ADC-11)
|
Operation languages
|
15 type of languages
|